Sargent 55-8975F LHR 32D Fail Safe Mortise Exit Device
Sargent 55-8975F LHR 32D Mort Exit Device, Fail Safe, is a Grade 1 mortise exit bar designed for superior performance and security. Featuring a wide stile pushpad, this 36-inch device is equipped to accept electrified trim functions and includes a request to exit switch for added convenience. The hex key dogging mechanism ensures reliable operation, while its satin stainless steel finish enhances durability and aesthetic appeal. Built to withstand high-traffic environments, the Sargent 80 Series exit devices exceed ANSI/BHMA Grade 1 standards for cycle and strength. With its modular construction and minimal moving parts, maintenance is simplified, making it an excellent choice for any facility looking for long-lasting security solutions. This device is specifically designed for single door applications and accommodates wood or metal doors with a thickness of 1-3/4″ to 2-1/4″. The Sargent 55-8975F is suitable for doors with widths ranging from 33″ to 36″ and requires a minimum stile size of 4-1/2″. Backed by a 5-year limited warranty, this exit device is a reliable choice for commercial installations. Experience peace of mind knowing that your building is equipped with one of the industry’s top exit devices.
Mort Exit Device, Fail Safe
Grade 1 Mortise Exit Bar, Wide Stile Pushpad, 36″ Device, Device to Accept Electrified Trim Function, Request to Exit Switch, Hex Key Dogging, Satin Stainless Steel Finish, Left Hand Reverse
The Sargent 80 Series exit devices are ideal for environments that require strong and durable security solutions that will last the life of the building. Available in rim, mortise, surface vertical and concealed vertical rod configurations, these exit devices easily exceed ANSI/BHMA Grade 1 requirements for cycle and strength. With modular construction and few moving parts, the 80 Series devices are maintenance-free and provide unsurpassed security for any facility. Plus, options are available for unique applications including delayed egress, alarmed exit and electric latch retraction making these exit devices the go-to product in your building.
The 8900 Series is for single door applications
8900 Mortise Lock Exit Device has concealed single point guarded latching for additional security and is designed for standard width stile applications on wood and metal doors.
- Door Types: Wood or metal 1-3/4″(44mm) Thick Door;Over 1-3/4″ specify thickness and order as a 31-option. 4-1/2″ (114mm) minimum stile
- Door Widths:E Rail – 24″ to 32″ (61cm to 81cm) No cutting required for 32″ door;F Rail – 33″ to 36″ (84cm to 91cm) No cutting required for 36″ door;J Rail – 37″ to 42″ (94cm to 107cm) No cutting required for 42″ door;G Rail – 43″ to 48″ (110cm to 122cm) No cutting required for 48″ door
Attributes
Accessible: No
Ada Compliance: No
Ansi: ANSI/BHMA A156.3
Baa Qualified: Yes
Burglar Rated: No
Commercial Residential: Commercial
Country of origin: USA
Device Length: 36″
Device Type: Mortise
Dogging Options: Hex Key Dogging
Door Material: Metal
Door Thickness: 1-3/4″ – 2-1/4″
Door Width: 33″ to 36″
Finish: 630/US32D
Finish Family: Matte Silver
Fire Rated: No
Fire Rating: No
Grade: Grade 1
Handing: Left Hand Reverse
Includes Cylinders: No
Includes Trim: No
Installation: Commercial
Limited Warranty: 5 Years
Mechanical Function: Device to Accept Electrified Trim
Minimum Stile Size: 4-1/2″
Origin: USA
Pack Height: 6″
Pack Length: 38″
Pack Qty: 1
Pack Width: 7.5″
Physical Appearance: Wide Stile Pushpad
Restrictions: None
Reversible: No
Series: 8900 Series Mortise Exit Devices
Ship Weight: 15 lbs.
Strike Standard: C908
Subtype: Mortise Exit Devices
Switch Type: Request to Exit
Trim Type: Less trim
Type: Exit Devices
Ul Listing: UL10C & UL305
Unit of Measure: Each
Resources
- 16- 816 Cylinder Dogging Kit (80 Series Exit Device) Installation Instructions
- 43-Flush End Cap Rail Cutting Installation Instructions
- 55-Signal Switch for 80 Series Installation Instructions
- 56-Electric Latch Retraction Exit Device Sell Sheet
- 565 & 665 Metal End Cap Kit Installation Instructions
- 57-Delayed Action 80 Series Exit Device Installation Instructions
- 57-Delayed Egress for 80 Series Exit Devices to ElectroLynx Connector System Installation
- 59-Electroguard Delayed Egress for 80 Series Exit Devices Installation Instructions
- 80 Series Brochure
- 80 Series Exit Device Environmental Product Declaration
- 816 Cylinder Dogging Kit Parts List
- 8300 Series Narrow Mortise Exit Devices Cut Sheet
- 8600/8700/8800/8900 Wide Stile Rail Assemblies Parts List
- AL- Alarmed Exit Device Installation Instructions
- Anti Vandal Pull Trim Instructions – 8800, 8900, PE80
- Basic Fundamentals – Exit Devices
- Electric Dogging for 80 Series Installation Instructions
- Mounting 80 Series Exit Device with Glass Bead Shim Kit Installation Instructions
- Thru-Bolt for 80 Series 8700,8800 and 8900 Installation Instructions
- Windstorm Solutions – Exit Devices






Reviews
There are no reviews yet.